Important!
Toensuresafeburningtheremustbeclearyellowflamesorclearembersatall
times.
Thefirewoodshouldnotbesmouldering.
10.Securethefire
DuethefollowingregulationAS/NZS2918thefiremustbeboltedsecuretothefloorto
complywiththeNewZealandStandard.Seebelow3.8.
3.5 Stability
Anapplianceshallbeinstalledwithsufficientstabilitysoasnottodetractfromthe
intendednormaloperationoftheappliancenortocreateahazardforusersofthe
appliance.
3.8Seismicrestraint
Whererequiredbytheregulatoryauthority,provisionshallbemadeforseismicrestraint
ofthefloorprotectorandtheappliance.Sufficientrestraintshallbeprovidedtoresista
seismicloadingequalto0.4timesthemassoftheappliance.Theloadshallbeapplied
horizontallyinanydirectionatthemidheightofthecombustionchamber.Theappliance
shallnotmove,tiltorbedislodgedfromitsinstalledpositionduringapplicationofthe
load.
Notes:
1. Theseismicloadingistobeappliedbeforethefluesystemisinstalled
2. Wheretheapplianceissecuredtothefloorprotectorthetestistobeappliedtothe
combinationatapointapproximately100mmabovethetopsurfaceofthefloor
protector.